Lenze DSD Instrukcja Użytkownika Strona 186

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 496
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 185
7Applications
7.21 Dimension the multi-axis system
186
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parallel connection of several regenerative power supply modules
[7-183] Parallel connection of several regenerative power supply modules
When the derating factors are complied with, the operation of several regenerative power sup-
ply modules in the DC-bus connection is permitted.
The arrangement in the DSD can only be dimensioned with regenerative power supply modules
9400.
The regenerative power supply modules can be each dimensioned separately in the DSD.
The selection table in the DSD provides regenerative power supply modules 9400 connected
in parallel (2 × E94... or 3 × E94...).
Single-axis application
For applications with a high regenerative power (e. g. unwinders and hoists) it may also be reason-
able to use a regenerative power supply module for a drive axis.
[7-184] One drive axis with supply/feedback
3 AC
DC bus
2
3
3
2
3
3
=
~
=
~
M
3~
2
M
3~
...
...
2
33
=
~
=
~
=
~
=
~
Regenerative power supply module
M
3
P
mot
P
gen
P
mot
P
gen
i
1
i
1,1
-
3 ~
DC
2
-
3 ~
0
Przeglądanie stron 185