HMI Designer
L
QM
EDBHMI-DEEN DE/EN 4.0
QKRKP aÉíÉêãáåÉ ÅçããìåáÅ~íáçå é~ê~ãÉíÉêë
The keypad and the controller communicate via the system bus (CAN). Define the communication
parameters for both devices, before the project is transmitted to the keypad.
`çããìåáÅ~íáçå é~ê~ãÉíÉêë çÑ íÜÉ ÅçåíêçääÉê
Mark the component 93xx in the project area and select Edit Parameters to open the
Device’s parameters dialog box:
Enter the controller address in the Device’s properties dialog box.
Ó The controller address is saved under code C0350 (CAN bus node address).
Confirm with OK.
qáé>
The value set under Controller address must be identical with the setting in the controller.
( Operating Instructions “9300 Servo inverter” or online documentation “9300 Servo PLC” on the CD-ROM “Drive
PLC Developer Studio”)