Lenze PLC Designer ApplicationTemplate (PLC Designer R3- Instrukcja Użytkownika Strona 86

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 177
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 85
Architecture: The ApplicationTemplate in detail
Default coupling
86
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
"DefaultCouplingMaster" methods - overview
9.4.3 The "DisableDefaultCouplingSlave" function
The "DisableDefaultCouplingSlave" function has the effect that the slave module decouples from
the state machine of the master module (during operation).
This function is required if...
...specific machine parts / machine modules are to be decoupled (during operation).
...a different response is required for the decoupled machine parts/machine modules than for
the higher-level machine module.
•The SMDisableDefaultCouplingSlave(TRUE) method call of a module application (MAP)
activates the function to decouple the slave from the master.
•The SMDisableDefaultCouplingSlave(FALSE) method call deactivates the function.
The module's intrinsic state machine cannot be coupled to the higher-level master module.
The state machine can control the subordinated slave modules (locally from the module
application) via the BaseChannel methods.
That way, the MFB_MachineControl state machine of the lower-level slave modules acts just
like the machine module with the activated SMDisableDefaultCouplingSlave method.
The higher-level master module ignores the status of a slave module for which the
DisableDefaultCouplingSlave function is activated.
Optionally, the error acknowledgement can be set via the higher-level master:
Identifier/function Transfer value/data type Description
baseChannelGetDefaultCouplingMaster
Disabled
• Queries the status of the
SMDisableDefaultCouplingMaster
method of the respective module.
MM_Address
L_EATP_MM_Address
Address of the module the current
state of which is to be queried.
The value "0" and the
L_EATP_CONST.OWNID constant
address the module's intrinsic ID.
Return value/data type
BOOL
TRUE: of the master is
deactivated
FALSE: The standard coupling of
the master is activated.
SMDisableDefaultCouplingMaster
• Activates/deactivates the standard
coupling of the master.
xValue
BOOL
TRUE: Deactivate the standard
coupling of the master
FALSE: Activate the standard
coupling of the master
: "Disable" = "TRUE"
L_EATP_GVL.xDisableGlobalErrorReset := FALSE; //default setting