Lenze Controller-based Automation Instrukcja Użytkownika Strona 46

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 45
4 System components
4.5 Bus systems
46
Lenze · Controller-based Automation · System Manual · DMS 1.4 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PROFINET (Logic)
PROFINET is recommendable for the following applications:
Extension and control of system parts that have already been automated with PROFINET and
another control system.
Use of field devices which do not support EtherCAT, CANopen and PROFIBUS.
PROFINET as logic bus combined with EtherCAT as motion bus.
The PROFINET bus system is a real-time capable, Ethernet-based bus
system. Lenze Controllers support logic functions when the PROFINET
bus system is used.
Communication manual "Controller-based Automation PROFINET®"
Here, further information on the bus system and configuration can be found.