Mechanical installation
Mounting steps
Fixing the mounting frame to the support arm
5
29
BA_CS9000DVI EN 4.0
With add−on component
1
0
1
3
6
4
5
2
1
4
0
4
CS57x0−006
How to proceed:
1. Check support arm system for professional mounting and sufficient carrying
capacity.
– See support arm documentation.
2. Stick the self−adhesive seal on the adapter plate on the side with the threaded
bolts.
3. Pull the connecting cables out of the support arm and screw the adapter plate
to the support arm .
– For screws see support arm documentation.
4. Screw the add−on component to the threaded bolts of the adapter plate .
– 4 spacer bolts on the inside/outside M5 x 20 mm
5. Stick the second self−adhesive seal on the add−on component .
6. Screw the mounting frame to the add−on component .
– 4 nuts M5 with washers Æ 5.3 mm
– 4 screws M5 x 8 mm with washers Æ 5.3 mm
Now you can connect the Command Station ( 33).