1 About this documentation
1.3 Terminology used
9
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1.3 Terminology used
Term Meaning
ACD Address Conflict Detection
Adapter EtherNet/IP slave
Drive Lenze inverters of the "Servo Drives 9400" product series
Inverter
Standard device
ARP Address Resolution Protocol
BOOTP Bootstrap Protocol
Code Parameter which serves to parameterise and monitor the drive. In normal usage,
the term is usually referred to as "Index".
Subcode If a code contains several parameters, they are stored in so-called "subcodes".
This manual uses a slash "/" as a separator between code and subcode
(e.g. "C00118/3").
In normal usage, the term is also referred to as "Subindex".
DHCP Dynamic Host Configuration Protocol
DSCP Differentiated Services Codepoints
EDS Electronic Data Sheet
»Engineer« PC software from Lenze which supports you during engineering
(parameterisation, diagnostics, and configuration) throughout the entire life
cycle, i.e. from planning to maintenance of the commissioned machine.
EtherNet/IP™ (EtherNet Industrial Protocol) is a fieldbus system based on
Ethernet which uses the Common Industrial Protocol™ (CIP™) for data exchange.
EtherNet/IP™ and Common Industrial Protocol™ (CIP™) are trademarks and
patented technologies, licensed by the user organisation ODVA (Open
DeviceNet Vendor Association), USA.
Explicit messages Explicit Messages are used to transfer parameter data.
HW Hardware
IGMP Internet Group Management Protocol
Implicit messages Implicit Messages are used to transfer I/O data.
"Class 1" connection I/O connection
"Class 3" connection Explicit connection
Level 2 EtherNet/IP performance level 2:
I/O Message Server including Explicit Message Server
Lenze setting Default settings of the device, preconfigured ex works.
Standard setting
PLC Programmable Logic Controller
QoS Quality of Service
RPI Requested Package Interval:
Interval requested between 2 telegrams for cyclic data transmission
»RSLogix 5000« Programming and development software from Rockwell for hosts (scanners) in
EtherNet/IP networks (e.g. Allen-Bradley Logix controllers).
Scanner EtherNet/IP master or client
Host
SW Software
TTL Time To Live:
Validity time of data packets in the EtherNet/IP network
UCMM Unconnected Message Manager