2 Safety instructions
Residual hazards
EDK94AZMS DE/EN/FR/ES/IT 8.0
34
l
H1sic_EN−UR_WARN_E94AZ−Filter
Residual hazards
{ Danger!
Dangerous electrical voltage
All power terminals remain live for up to three minutes after mains
disconnection.
Possible consequences:
ƒ Death or severe injuries when touching the power terminals.
Protective measures:
ƒ Switch off the power supply and wait for at least three minutes before
working on the power terminals.
ƒ Make sure that all power terminals are deenergised.
O Warnings!
Conditions of Acceptability:
ƒ The products covered by this report are only intended for use with Power
Conversion Equipment (inverters).
ƒ Consideration shall be given to the field wiring leads. No strain relief test
was performed on the leads.
ƒ The devices in this report are only evaluated for factory wiring use.
ƒ Temperature tests were performed with hook mounted drive.