Electrical installation
Wiring
Operation with ECSxE power supply module
5
31
EDBCSXKXXX EN 1.0
5.6 Wiring
5.6.1 Operation with ECSxE power supply module
Install the capacitor module ECSxKxxx between the power supply module and the axis
module(s).
If the total cable l ength in the DC-bus connection is longer than 5 m, install the capacitor
module as close as possible to the axis module with the highest power.
Stop!
ƒ
Permanently bridge the charging current limitation (X26) of the capacitor
module(X26=HIGH).
ƒ
Only release the controller (X6/SI1 = HIGH) if the power supply module
ECSxE displays ”Ready for operation” (X6/DO1 = HIGH).
L3
N
PE
L1
L2
F1...F3
Z1
F4
K1
ECSxKxxx
K1
K1
L1 L2
L3
ECSxExxx
PE
X21
+UG
+UG
+UG
+UG
+UG
-UG
-UG
-UG
-UG
-UG
PE
PE
PE
PE
PE
X22
X23
Off
On
+UG
BR1
X26
BR0
PES
PES
U
V
W
ECSxAxxx
X23
PE
X24
B1 B2
X25
X7
M
3~
PE
PES
PES
R
J
*1
2
6
...
T1
T2
X6
DI1
DI2
DO1
D24
+24V
GND
GND
24VDC
+
-
Ctrl. enable
K1
ECSXX004
Fig.5-2 Wiring of t he capacitor module ECSxK with power supply module ECSxE
HF shield termination by large-surface PE connection
Twisted cables
*1 System cable - feedback
Ctrl.
enable
Terminal X6/SI1 of the connected axis modules (controller enable)