Function library
Function blocks
3.5.49 OR operation (OR)
3−230
l
EDSVS9332P−EXT DE 2.0
3.5.49 OR operation (OR)
Purpose
Logic OR operation of digital signals. The operations are used for controlling functions or creating
status information.
OR1
1
OR1-IN1
OR1-IN2
OR1-IN3
OR1-OUT
C0831/1
C0831/2
C0831/3
C0830/1
C0830/2
C0830/3
Fig. 3−175 OR operation (OR1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
OR1−IN1 d C0831/1 bin C0830/1 2 1000
OR1−IN2 d C0831/2 bin C0830/2 2 1000
OR1−IN3 d C0831/3 bin C0830/3 2 1000
OR1−OUT d
OR2
1
OR2-IN1
OR2-IN2
OR2-IN3
OR2-OUT
C0833/1
C0833/2
C0833/3
C0832/1
C0832/2
C0832/3
Fig. 3−176 OR operation (OR2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
OR2−IN1 d C0833/1 bin C0832/1 2 1000
OR2−IN2 d C0833/2 bin C0832/2 2 1000
OR2−IN d C0833/3 bin C0832/3 2 1000
OR2−OUT d