Przeglądanie stron 40
Mechanical installation
Mounting
Mounting the fixed cover
5
l
41
BA 12.0023−EN 7.0
5.4.8 Mounting the fixed cover
for size 09, 11 and 14
) Note!
This cover is supplied loose on delivery!
2
x
x
3x120°
1
3
Fig. 10
1 Protection cover
2 Cheese head screw
3 Thread reducing sleeve
1. Screw the three reducing bushes (3) into the flange with a screwdriver so they are
flush and staggered by 120°.
2. Fasten the protective cap (1) over the reducing bushes (3) on the flange using three
cheese head screws (2).