Lenze c300 Instrukcja Użytkownika Strona 98

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 195
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 97
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 98
12 Visualisation with »VisiWinNET®«
12.2 System structure
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.2 System structure
»VisiWinNET®« consists of...
the »VisiWinNET®« Engineering tool on the Engineering PC: and
the »VisiWinNET®« runtime on the Controller: .
By means of »VisiWinNET®« you create the visualisations on the Engineering PC.
The »VisiWinNET®« Engineering tool executes the associated »VisiWinNET®« runtime of the
controller.
By means of the »VisiWinNET®« Remote Access Manager, you transfer the visualisations to the
controller.
Activate parameter 97 "Activate VisiWinNET Remote Access " in »WebConfig« to start the
Remote Access Manager.
TCP/IP serves as a standard for data transmission.
The »VisiWinNET®« Runtime is able to access the following variables:
PLC variables (Logic/Motion),
Parameters of the controller (data manager)
Parameters of the devices (via the fieldbus driver).
Przeglądanie stron 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 194 195

Komentarze do niniejszej Instrukcji

Brak uwag