Cam Designer Basic
Operation
Create a new project
24 2.1 EN - 09/2005 L
How to define the properties of the master...
1. Go to the Master dialog box and select the properties of the master.
•The Name of the master is indicated on your worksheet.
•The Cycles are the maximum number of operating cycles per minute.
2. Click Next to proceed with the next step.
6.1.2 Step 2: Defining the properties of the slave axis
The entries in the axes reflect the machine constants. Therefore, only work with real val-
ues.
Enter the indicated values into the dialog box Slave.
Note!
If you use a virtual master, enter in the group field "Machine" under "Gearbox
factor" 100 in the input field z2 and 1 in the input field z1. This serves to achieve
a higher resolution of the master angle.