Introduction
Creating/preparing import data
16 1.1 EN - 05/2005 L
Cam type
The cam type is defined through the following numbers:
Entry Cam type
1 Position cam in positive effective direction
Switch on and switch off point are defined by positions.
The cam switches if the direction of the axis is positive (positive speed).
2 Position cam in negative effective direction
Switch on and switch off point are defined by positions.
The cam switches if the direction of the axis is negative (negative speed).
3 Position cam with bipolar effective direction
Switch on and switch off point are defined by positions.
The cam switches in positive and negative direction of the axis.
11 Time-based cam in positive effective direction
The cam switches on at the switch on point if the direction of the axis is positive (positive speed).
After the selected time, the cam switches off.
12 Time-based cam in negative effective direction
The cam switches on at the switch on point if the direction of the axis is negative (negative
speed).
After the selected time, the cam switches off.