6 Commissioning of the PROFINET
6.2 The commissioning steps in detail
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4. Go to the Standard project dialog window and select the target system in the Device
selection field:
Lenze Logic Controller
For controlling inverters which perform simple motions, do not have any motion
functionality or are controlled via pure PLC functionalities.
Lenze Motion Controller
Only if an additional Motion bus with EtherCAT is used (see Mixed operation PROFINET
with EtherCAT ( 32))
Further optional project settings
Selection of the Lenze control technology release version
Selection of the compiler version
Selection of the programming language:
Sequential function chart (SFC)
Instruction list (IL)
Continuous function chart (CFC)
Function block diagram (FBD)
Ladder diagram (LD)
Structured text (ST)
5. Confirm the selection by clicking OK.