7.5.11.6 Setpoint sum
Only HVAC” controllers
Code Name Possible settings IMPORTANT
C
o
d
N
a
m
Lenze Choice Info
I
M
P
O
R
T
A
N
T
C049* Additional setpoint -480.00 {0.02 Hz} 480.00 Display only
Function In controlled operation(C005 = -1-, -2-) the setpoint sum can be generated with
the signal of the analog input (terminal 8) or
the digital frequency at terminal E1 or
the function Motor potentiometer or
the process setpoint C046 (LECOM).
The additional setpoint is indicated under C049.
Special features The displayvalue of the parameter canbe relatedtoanapplication datum(C500, C501).
(see chapter7.6.3)