EDKCSCE040 DE/EN/FR 3.0
Scope of supply
Position Description Number
Power supply module ECSCExxx 1
Accessory kit with attachment material 1
Mounting instructions 1
Drilling jig 1
Note!
The ECSZE000X0B connector set must be ordered separately.
Connections and interfaces
Position Description Detailed
information
X22 Connections
l External brake resistor
l DC−bus voltage
l PE
 88
LEDs: Status and fault display
X1 Automation interface (AIF) for
l Communication module
l Operating module (XT keypad)
 100
X2 PE connection AIF
X3 Not assigned
X4 CAN connection
l System bus (CAN)
l Interface for
master control and other modules
PC/HMI for parameterisation and diagnostics
 101
X6 Connections
l Low−voltage supply
l Digital inputs and outputs
l Thermostat contacts
 99
S1 DIP switch
l CAN node address (device address in the CAN network)
l CAN baud rate
X21 Mains connection  85
Status displays
LED
Description
Red Green
Off On Power supply module is enabled, no fault
Off Blinking Power supply module is inhibited (CINH), switch−on inhibit
Blinking, 1 Hz Off Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active
Blinking, 3 Hz Off Message active
Blinking, 1 Hz Blinking Warning active with inhibited module
Blinking, 1 Hz On Warning active with enabled module