Lenze EVS9332xS Instrukcja Użytkownika Strona 124

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 264
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 123
Function library
Function blocks
3.2.26 Digital frequency ramp function generator (DFRFG)
3−72
l
EDSVS9332S−EXT EN 2.0
3.2.26.4 RESET
DFRFG−RESET = HIGH:
l Resets setpoint phases which are internally added.
l Activates the profile generator.
l HIGH−LOW edge at DFRFG−RESET: Detecting the setpoint phase.
3.2.26.5 Detect phase difference
Monitoring the phase difference between input DFRFG−IN and output DFRFG−OUT.
l Set limit value of monitoring via C0754.
l Activates the monitoring: DFRFG−FAIL = HIGH
l Storing the signal until DFRFG−RESET = HIGH.
l The profile generator can accept a phase difference of up to ±2140000000 inc (= 32000
revolutions).
Przeglądanie stron 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 263 264

Komentarze do niniejszej Instrukcji

Brak uwag