4 Technical data
General data
EDK82ZAFCC−001 DE/EN/FR 5.0
40
H1_Daten−td_klemm−x3
4 Technical data
General data
Field Values
Communication profile Based on CANopen
Communication medium ISO 11898
Network topology
Line (terminated with 120 on both sides)
Node addresses Max. 63
Baud rate [kbps] 20, 50, 125, 250, 500
Operating conditions
Ambient conditions
Climate
Storage IEC/EN 60721−3−1 1K3 (−25 to +60 °C)
Transport IEC/EN 60721−3−2 2K3 (−25 to +70 °C)
Operation Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
Pollution EN 61800−5−1 Degree of pollution 2
Connection terminals
Terminal X3/
28
Input resistance: 3.3 k
External supply: U(ext) = 12 V DC − 0 % ... 30 V DC + 0 %
20 Voltage: U = 20 V
Load capacity: I
max
= 30 mA
Reference: GND1