Lenze E84AYCIB Instrukcja Użytkownika Strona 52

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 75
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 51
E84AYCIB communication manual (INTERBUS)
Parameter data transfer
Supported PMS services
52 L EDS84AYCIB EN 4.0 - 11/2010
9.3.7 Status
The "Status" PMS service provides status information about the controller.
The controller provides the following values:
Status Value Description
Logical status 0 = ready for communication Information about the current operating
mode of the controller with regard to
communication
Physical status 0 = ready for operation (device state
"OPERATION ENABLED")
1 = ready for operation to a limited extent
(all other device states)
Information about the current operating
status of the
controller.
Local Detail 0 Is not supported.
Przeglądanie stron 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 74 75

Komentarze do niniejszej Instrukcji

Brak uwag