Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17 13
3 Product description
3.3 Product features
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3 Product features
Interface module for the INTERBUS communication system to be connected to the expansion
slots of the Servo Drives 9400
The communication module can either be supplied internally by the standard device or
externally by a separate voltage source.
Slave functionality
DIP switch settings:
Number of process data words and parameter data words
Baud rate (500 kbps or 2 Mbps)
Bus coupling via remote bus according to the RS485 standard
Up to 10 process data words (20 bytes) can be used.
0, 1, 2 order 4 parameter data words can be used.
The parameter data is transmitted in accordance with the Peripherials Communication Protocol
(PCP).
Access to all Lenze parameters
Support of the PMS services:
•Initiate
•Abort
Reject
•Read
•Write
•Get-OD
•Identify
Status