DMS 3.1 EN 01/2011 TD17 L 61
Control technology | EtherCAT communication manual
Commissioning of the system
Detailed commissioning steps
How to set the DC synchronisation:
1. Configure the synchronisation of the EtherCAT slaves via distributed clocks (DC).
Set the Distributed clocks (DC) cycle time at the EtherCAT Master:
The DC cycle time to be set in the »EtherCAT Configurator« must be identical to
the EtherCAT task cycle time set in the »PLC Designer«.
Select the cycle times, according to the technical data, between 1 and 10 ms.
The (basic) cycle time set here is valid for all Logic and Motion nodes
synchronised by distributed clocks.