Lenze EtherCAT control technology Instrukcja Użytkownika Strona 80

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 204
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 79
Control technology | EtherCAT communication manual
Commissioning of the system
Checking the system startup
80 L DMS 3.1 EN 01/2011 TD17
7.3 Checking the system startup
To check whether the system has started up correctly, you can do the following
Evaluation of the boot-up error message of the SM_DriveBasic.lib library
( 80);
Evaluation of the Axis_IO_Group state
( 81);
Evaluation of the axis state
( 82).
7.3.1 Evaluation of the boot-up error message of the SM_DriveBasic.lib library
To check that the system has started up correctly, you can evaluate the boot-up error. For
this purpose, the scope of the global variables contained in the SM_DriveBasic.lib library
includes the element g_strBootupError. This element displays error messages in text
form:
g_strBootupError = no error
no error indicates that the system has started up correctly:
Note!
Checking of the system startup is only possible for SoftMotion target systems.
Przeglądanie stron 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 203 204

Komentarze do niniejszej Instrukcji

Brak uwag