9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
202 L EDS94ARNExxxx EN 2.3 - 06/2014
8.6.2 Resetting an error message
An error message with the response "Fault", "Trouble", or "Warning locked" must be reset
explicitly (acknowledged) after the cause of the error has been eliminated.
To reset (acknowledge) a pending error message, execute the device command
C00002
= "43: Reset error".
Tip!
When an online connection to the regenerative power supply module has been
established, use the Diagnostics tab of the »Engineer« and click Reset error to reset
a pending error message.