Lenze E94AxHE Technology Application Actuating drive - S Instrukcja Użytkownika Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 38
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 20
EDS94TA10010xxxx EN 1.1 - 10/2008 L 21
9400 Technology applications | Actuator – speed
Parameter setting & configuration
Speed setpoint conditioning
4.3.3 Speed ramp generator
[4-5] Ramp generator (schematic diagram)
In order to avoid setpoint step-changes the speed setpoint passes a ramp generator with a
parameterisable acceleration/deceleration and S-ramp time before it is transmitted to the
basic drive function "Speed follower".
r Parameter setting: Tab Application parameters dialog level Overview
Gain Invert setpointSelection
LS_Speed...
M
Speed
setpoint
DI2DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameter Lenze setting
Value Unit
C03502 Basic acceleration time 1.000 s
C03503 Basic deceleration time 1.000 s
C03504 Basic S-ramp time 0.100 s
C03510 Profile mode Linear ramps
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 37 38

Komentarze do niniejszej Instrukcji

Brak uwag