EDS94AYFLF EN 3.2 - 10/2010 L 13
Digital frequency extension module | Parameter setting & configuration
Digital frequency input
Parameter setting
2.2.4 Use of machine parameters for scaling
This function extension is available from software version V3.0 onwards!
The input DFIN_AxisData can be used to transfer the machine parameters of the own
motor/drive or of a higher-level drive to the system block LS_DigitalFrequencyInput.
If valid machine parameters are applied to the input DFIN_AxisData, then the outputs
for the actual position and the actual speed are evaluated on the basis of the
transferred machine parameters (gearbox factors, encoder resolution).
The position is scaled to the set measuring system/traversing range.
The encoder mounting position can be parameterised under C13015
/ C14015.
If the input DFIN_AxisData remains unused, the system block continues to operate as
before. In this case the units are scaled to revolutions.
Tip!
With this function extension, the system block LS_DigitalFrequencyInput can be
coupled directly to a master value measuring system. The system block then uses
the units of this measuring system for processing.
Short overview of the parameters for this function extension:
Parameter Info Lenze setting
Value Unit
C13015 C14015 Encoder mounting position DFIN Clockwise rotation
C13035/1 C14035/1 Position unit DFIN -
C13035/2 C14035/2 Speed unit DFIN -
C13036 C14036 Actual position DFIN - Unit
C13037 C14037 Actual speed DFIN - Unit/t
Digital frequency extension module in module receptacle MXI1
Digital frequency extension module in module receptacle MXI2
Greyed out = display parameter