Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParPDO15 - Communication settings PDO1 ... PDO5
42 L DMS 1.0 EN - 07/2011 - TD05
Inputs
Identifier/data type Information/possible settings
bExecute
BOOL
FALSEÊTRUE Start parameter setting
dwHandle
DWORD
9400 ServoPLC: Handle created by FB L_CanInit
Drive PLC, 9300 Servo PLC, ECS: 10
byNodeAdr
BYTE
1 ... 127 CAN node address of the I/O system
bStoreParameter
BOOL
TRUE Save parameter set at the end of the parameterisation process.
Then the NMT command "Reset Node" is sent to the I/O system.
wCobID...
_RxPDO1 ... _RxPDO5
_TxPDO1 ... _TxPDO5
WORD
Identifier
for PDO1 ... PDO5 (PLC I/O system)
for PDO1 ... PDO5 (I/O system PLC)
0 Automatic allocation of the identifiers
( 45)
> 0 Value of the set identifier
byTransmissionType...
_RxPDO1 ... _RxPDO5
_TxPDO1 ... _TxPDO5
BYTE
Transmission mode
for PDO1 ... PDO5 (PLC I/O system)
for PDO1 ... PDO5 (I/O system PLC)
0 Event-controlled
1 Time-controlled
2 Event-controlled with higher-level cycle time
3 PDO deactivated
tCycleTime...
_RxPDO1 ... _RxPDO5
_TxPDO1 ... _TxPDO5
TIME
Cycle time
for PDO1 ... PDO5 (PLC I/O system)
for PDO1 ... PDO5 (I/O system PLC)
0 ... 65535 Cycle time in [ms]
tInhibitTime...
_TxPDO1 ... _TxPDO5
TIME
Blocking time
for PDO1 ... PDO5 (I/O system PLC)
0 ... 65535 Blocking time in [ms]