System bus (CAN) for Lenze PLC devices
CAN−AUX system blocks
9.3 CANaux3_IO (node number: 36)
9−1
L
PLC−Systembus EN 2.0
9.3 CANaux3_IO (node number: 36)
This SB serves to transmit event−controlled or time−controlled process data via the system bus.
· The setting of the transmission mode (event− or time−controlled) is effected via C2456. (^ 3−6)
· A sync telegram is not required.
CANaux3_nInW1_a
CANaux3_nInW2_a
CANaux3_bInB _b0...15
CANaux3_bInB _b16...31
Byte
7
8
5
6
3
4
1
2
Byte
7
8
5
6
3
4
1
2
CANaux3_nOutW1_a
CANaux3_nOutW2_a
CANaux3_nOutW3_a
CANaux3_bFDO _b16...31
CANaux3_dnOutD1_p
CANaux3_IO
DINT
WORD
WORD
WORD
16 x BOOL
DINT
Output user data
(8 bytes)
Input user data
(8 bytes)
L
H
L
H
CANaux3_bFDO _b0...15
16 x BOOL
CANaux3_nOutW4_a
WORD
WORD
WORD
16 x BOOL
16 x BOOL
CANaux3_nInW3_a
CANaux3_nInW4_a
WORD
WORD
CANaux3_dnInD1_p
C2493/8
C2493/9
C2493/10
C2493/11
C2492/8
C2492/9
C2492/5
C2491/6
C2492/10
C2492/11
CAN-AUX System bus interface
Fig. 9−3 CANaux3_IOsystem block
Tip!
Via C2457/3 you can set the monitoring time for the data reception. (Lenze setting: 3000 ms)
· Further information on this subject can be found in chapter 3.12.1. (^ 3−11)