DDS EN 2.3
8.2 Code initialization values
The code initialization values are an object on tab Resources in the
Object Organizer
.
Initialization value priority
Reset modes Descending priority
Reset
Code initialization value
Parameter Manager
Reset (cold)
Code initialization value
Parameter Manager
Reset (bootstrap)
Deletes the complete program in the automation system,
leaving no value valid.
Program download
Code initialization value
Parameter Manager
Mains switching The last value saved with C0003 is valid.
Load default Parameter Manager
Use this object to initialize codes with an initial value. Not only the codes generated in the Parameter
Manager can be initialized, but also all system codes. These codes are permanently saved in the
automation systems parameter set at the end of the download.
All selected codes are overwritten in the parameter set.
Any code can be written.
Overwritten initial values set in the Parameter Manager are only stored in the default setting.
(See codes C0002 and C0003)
The entered codes are saved one after the other in the parameter set.
Exception: Codes C0086 and C0025 are modified on initialization start as they affect other
codes.
Unknown codes and initialization values beyond the code value limits are ignored by the
automation system.