Przeglądanie stron 59
4 Drive interface
4.2 Device commands
60
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.15 Inhibit controller
The C00002 = "41: Inhibit controller" device command is used to inhibit the controller ("controller
inhibit"), i.e. the power output stages in the controller are inhibited and the speed/current and
position controllers of the motor control are reset. The motor becomes torqueless and coasts unless
it is already at standstill.
The controller can also be inhibited by other sources, e.g. via the digital input RFR or through the
application.
C00158
provides a bit coded representation of all active sources/triggers of a controller inhibit.
Tip!
This device command can also be activated via the icon in the Toolbar.
Related device commands
Enable controller
( 61)
Note!
This device command has no status display in C00003, i.e. the display remains
unchanged showing the previous device command status.