Lenze 9400 Instrukcja Użytkownika Strona 60

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 954
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 59
4 Drive interface
4.2 Device commands
60
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.15 Inhibit controller
The C00002 = "41: Inhibit controller" device command is used to inhibit the controller ("controller
inhibit"), i.e. the power output stages in the controller are inhibited and the speed/current and
position controllers of the motor control are reset. The motor becomes torqueless and coasts unless
it is already at standstill.
• The controller can also be inhibited by other sources, e.g. via the digital input RFR or through the
application.
• C00158
provides a bit coded representation of all active sources/triggers of a controller inhibit.
Tip!
This device command can also be activated via the icon in the Toolbar.
Related device commands
Enable controller
( 61)
Note!
This device command has no status display in C00003, i.e. the display remains
unchanged showing the previous device command status.
Przeglądanie stron 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 953 954

Komentarze do niniejszej Instrukcji

Brak uwag