Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 645
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inside the device: Fan is defective [0x00770011]
Device utilisation Ixt > C00123 [0x00780000]
Device utilisation Ixt > 100 % [0x00780001]
Motor load I²xt > C00127 [0x00780002]
Motor load I²xt > C00120 [0x00780003]
Module ID (decimal) Error ID (decimal)
119: Temperature monitoring 17
Response (Lenze setting printed in bold) Setting: C00611 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Speed of internal fan is too low, e.g. due to dirt. Check/clean fan.
Module ID (decimal) Error ID (decimal)
120: Analog signal monitoring 0
Response (Lenze setting printed in bold) Setting: C00604 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Frequent and too long acceleration processes with
overcurrent > C00123
.
Check drive dimensioning.
Module ID (decimal) Error ID (decimal)
120: Analog signal monitoring 1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Frequent and too long acceleration processes with
overcurrent.
Check drive dimensioning.
Module ID (decimal) Error ID (decimal)
120: Analog signal monitoring 2
Response (Lenze setting printed in bold) Setting: C00606 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Motor is thermally overloaded, e.g. due to:
• impermissible continuous current
• frequent or too long acceleration processes
• Check drive dimensioning.
•Check setting in C00127
.
Module ID (decimal) Error ID (decimal)
120: Analog signal monitoring 3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Motor is thermally overloaded, e.g. due to:
• impermissible continuous current
• frequent or too long acceleration processes
• Check drive dimensioning.
•Check setting in C00120
.
Przeglądanie stron 644
1 2 ... 640 641 642 643 644 645 646 647 648 649 650 ... 953 954

Komentarze do niniejszej Instrukcji