What is the ApplicationTemplate PackML?
Elements of the ApplicationTemplate PackML
22
Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3. Add the ENUM value for this mode to the configuration block.
4. Add the new mode to ModApp1 by copy/paste of an already available mode and rename it,
example: ExampleMode.
5. Instance the newly created mode (FB) in the declaration part of the MAP:
6. Add the additional mode to the modes method and assign the ENUM value of the new
mode.
Changeover of the operating modes/Modes
After the additional mode has been implemented, the state machine and the changeover of the
modes can be operated with the PackML tags.