9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
64 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.17 MarkSynchronizationShaft
Is an instance of Function
L_LdPosCtrlLin Time-controlled profile generation with linear acceleration/deceleration ramps for
mark synchronisation (master value).
Mark synchronisation (master value)
(C 34)
Parameter Possible settings Information
C03620 Positioning mode
0 Absolute positioning without limit
stop:
When the positioning process is
started (bExecute = TRUE), the
outputs dnPosOut_p and
dnSpeedOut_s are led to the
target position using the set
profile parameters.
The traverse path results from
the difference between current
position dnActPos_p and target
position dnSetPos_p.
A new positioning profile is
started as soon as the target
position changes. An edge
change at the control input
bExecute is not required for this
purpose.
Lenze setting
1 Absolute Positioning with limit stop:
When the positioning process is
started (bExecute = TRUE), the
outputs dnPosOut_p and
dnSpeedOut_s are led to the
target position using the set
profile parameters.
The traverse path results from
the difference between current
position dnActPos_p and target
position dnSetPos_p.
When the set position has been
reached (bInTarget = TRUE), a
FALSEÊTRUE edge must occur at
the control input bExecute to
start a new positioning process.
2 Relative positioning with limit stop:
When the positioning process is
started (bExecute = TRUE), the
outputs dnPosOut_p and
dnSpeedOut_s are led to the
target position using the set
profile parameters.
The traverse path is selected
directly via the input dnSetPos_p.
When the set position has been
reached (bInTarget = TRUE), a
FALSEÊTRUE edge must occur at
the control input bExecute to
start a new positioning process.