9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
74 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.24 TouchProbePositionShaft
4.14.25 TouchProbePositionTool
Is an instance of Function
L_SdSetPosition Mark synchronisation (master value):
Conversion of the TP position selected in the real units of the machine via C03612
into a position in [increments].
Mark synchronisation (master value)
(C 34)
Parameter Possible settings Information
C03612 -214000.0000 unit 214000.0000 Position value
Initialisation: 0.0000 unit
C03613 String of digits Position unit
•Read only
C03614 -2147483647 2147483647 Status
•Read only
Is an instance of Function
L_SdSetPosition Mark synchronisation (setpoint):
Conversion of the TP position selected in the real units of the machine via C03846
into a position in [increments].
Mark synchronisation (setpoint)
(C 39)
Parameter Possible settings Information
C03846 -214000.0000 unit 214000.0000 Position value
Initialisation: 0.5000 unit
C03847 String of digits Position unit
•Read only
C03848 -2147483647 2147483647 Status
•Read only