EDS94TA10040xxxx EN 1.1 - 10/2008 L 65
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
C3621 Deactivation mode
0 Positioning function deactivated:
The position output dnPosOut_p
is set to 0.
The status signal bInTarget is
reset to FALSE.
Lenze setting
1 Positioning function changes to the
stand-by state:
The position output dnPosOut_p
is held on the current position
dnActPos_p.
The status signal bInTarget is
reset to FALSE.
2 Positioning function changes to the
stand-by state:
•If bSetPosZero = FALSE:
The position output dnPosOut_p
is held on the set position
dnSetPos_p.
•If bSetPosZero = TRUE:
The position output dnPosOut_p
is held on zero.
The status signal bInTarget is
reset to FALSE.
C03622/1 String of digits Position unit
•Read only
C03622/2 String of digits Speed unit
•Read only
C03623/1 0.0000 unit/t 214748.3647 Positive traversing speed
Initialisation: 3600 unit/t
C03623/2 0.0000 unit/t 214748.3647 Negative traversing speed
Initialisation: 3600 unit/t
C03624 -214748.3647 unit/t 214748.3647 Reference speed
Read only (generated from the
machine parameters applied at
the input AxisData)
Reference value for selecting
speeds.
C03626/1 0.010 s 130.000 Acceleration ramp
Initialisation: 1.000 s
Reference = reference speed
(display under C05054)
C03626/2 0.010 s 130.000 Deceleration ramp
Initialisation: 1.000 s
Reference = reference speed
(display under C05054)
C03626/3 0.010 s 130.000 Stop ramp
Initialisation: 1.000 s
Reference = reference speed
(display under C05054)
C03635 -2147483647 unit/t 2147483647 Speed at the output
•Display of the dnSpeedOut_s
output signal in the real unit of
the machine.
C03637 -214748.3647 unit 214748.3647 Position at the output
•Display of the dnPosOut_p output
signal in the real unit of the
machine.