Error messages
The following error messages have been stored:
Error number Description
411 TouchProbeSelect incorrect: TP channel does not exist
TouchProbeSelect > 1 in the case of ECSxM
TouchProbeSelect > 2 in the case of 9400
412 TouchProbeMode incorrect:
TouchProbeMode > 1 in the case of ECSxM (Only ’single measurement’ is
supported.)
TouchProbeMode > 2 in the case of 9400
413 TouchProbeEdge incorrect: When "TouchProbeSignal = Zero pulse" is
selected, only evaluation of ’positive edge’ is possible
TouchProbeMode > 1 in the case of ECSxM (Only ’single measurement’ is
supported.)
TouchProbeMode > 2 in the case of 9400
414 TouchProbeEdge incorrect: Requested edge evaluation does not exist
TouchProbeEdge > 2 in the case of ECSxM (Only positive or negative edge
possible.)
TouchProbeEdge > 4 in the case of 9400 (Type of edge evaluated not
supported.)
415 TP channel not free:
TP channel has already been activated by means of other block.
416 Touch Probe is not possible for the currently selected process data mapping.
417 Internal error / TP channel not free:
TP channel has already been activated by means of other block.
418 Internal error:
Timeout during assignment of the drive