Lenze L-force I/O System 1000 Instrukcja Użytkownika Strona 92

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 99
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 91
L-force Controls | I/O System 1000
Application examples
Communication between I/O system 1000 and Inverter Drive 8400 via CAN fieldbus
92 L 2.0 EN - 11/2010
9 Application examples
9.1 Communication between I/O system 1000 and Inverter Drive 8400 via CAN fieldbus
Requirements
The I/O system 1000 station is to communicate with an Inverter Drive 8400 via a CAN
fieldbus.
The "Speed actuating drive" application is to be extended by CANIN2 and CANOUT2.
The "bJogSpeed1" JOG value is to be activated via bit 1 of the "DI 8, DC 24V" electronic
module.
The "bDriveReady" bit is to be output to bit 1 of the "DO 8, DC 24V" electronic module.
How to proceed
1. Search for devices connected to the fieldbus
Execute the FileNew... command to call the Start-up wizard.