Lenze PLC Designer PLC-Designer (R2-x) SoftMotion Instrukcja Użytkownika Strona 137

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 290
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 136
L-force | PLC Designer - SoftMotion
The SM_PLCopen.lib library
POUs for the motion control of individual axes
137 L DMS 5.2 EN 03/2011 TD17
Inputs (VAR_IN)
Execute : BOOL (default: FALSE)
The program organisation unit is activated on a rising edge.
ArraySize : INT
Size of the array (max. 1..100)
Scale : REAL (default: 1)
General scaling factor for the profile
Offset : REAL
General offset for the profile [u]
Outputs (VAR_OUT)
Done : BOOL (default: FALSE)
TRUE indicates that the desired distance has been covered.
CommandAborted : BOOL (default: FALSE)
The motion that had started was interrupted by another function block acting on the same
axis (exception: MoveSuperImposed).
Error : BOOL (default: FALSE)
TRUE indicates an error in the function block.
ErrorID : SMC_Error (INT )
Error number
Przeglądanie stron 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 289 290

Komentarze do niniejszej Instrukcji

Brak uwag