L-force | PLC Designer - SoftMotion
The SoftMotion drive interface
Drive element <BusInterfaceName>Drive.lib
50 L DMS 5.2 EN 03/2011 TD17
3.3.1.3 The structure of LenzeECS_AXIS_REF
Variable Data type Description
byDriveState BYTE Status of the drive (internal use)
wStatusWord WORD Status word C0150 (ECSxM) / 6041
hex
(9400)
wStatusWord2 WORD Status word2 C0155 (ECSxM)
wControlWord WORD Control word C0135 (ECSxM) / 6040
hex
(9400)
wStatusWordOld WORD Last status word (internal use)
dwSetPosition DWORD Target position sent to the drive (read only)
byStatusInfo BYTE Bits 8 ... 11 of the status word (ECSxM)
byErrAcknCounter BYTE Error counter (internal use)
bHWLimitsActive BOOL TRUE if a limit switch is activated (ECSxM)
fLimitSwitchDeceleration LREAL Speed deceleration for stopping at the limit switch (if
0, no ramp is available), ECSxM only
mcstopLS MC_Stop Internal use
strConfigFile STRING Complete file name and path of the configuration
file
acit Internal use
txList, rxList, txPDOs, rxPDOs Internal use
byActOpMode BYTE Object 6061
hex
(9400)
bySetOpMode BYTE Object 6060
hex
(read only), 9400 only
bOldReference BOOL Internal use
byDigitalInputs,
byDigitalOutputs
BYTE Digital inputs (60FD
hex
) and
outputs (60FE
hex
/1), 9400 only
crap SMC_CANReadAllParams Internal use
pParameterlist POINTER TO
CAN_InitTelegram
Parameter list (internal use)
wp LenzeECSWriteParameter Written parameters ECSxM (internal use)
rp LenzeECSReadParameter Read parameters ECSxM (internal use)