Configuration
Basic configurations
8
8.5
8.5−8
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0108 100.00 −199.99 {0.01 %} 199.99 FCODE (AOUT gain)
Freely configurable code for
relative analog signals
See system
manual
(extension)
1 FCODE (GAIN) AOUT1−GAIN
2 FCODE (GAIN) AOUT2−GAIN
C0109 −199.99 {0.01 %} 199.99 FCODE (offset AOUT)
Freely configurable code for
relative analog signals
See system
manual
(extension)
1 FCODE
(OFFSET)
0.00 AOUT1−OFFSET
2 FCODE
(OFFSET)
0.00 AOUT2−OFFSET
C0114
0
1
HIGH active
LOW active
DIGIN polarity
Polarity of the terminals X5/Ex
See system
manual
(extension)
1 DIGIN1 POL 1 X5/E1
2 DIGIN2 POL 1 X5/E2
3 DIGIN3 POL 0 X5/E3
4 DIGIN4 POL 0 X5/E4
5 DIGIN5 POL 0 X5/E5
C0116
® selection list 2
Signal configuration of the free
digital outputs (FDO)
Free digital outputs can only be
evaluated when they are linked
to automation interfaces
See system
manual
(extension)
1 FDO−00 1000 FIXED0
2 FDO−01 15000 DCTRL−TRIP
3 FDO−02 30002 ENDED
4 FDO−03 30014 VTRAV−REA
5 FDO−04 30104 PF04
... ... ... ...
10 FDO−09 30109 PF09
11 FDO−10 30110 PF10
12 FDO−11 30111 PF11
... ... ... ...
21 FDO−20 30120 PF20
22 FDO−21 30121 PF21
... ... ... ...
31 FDO−30 30130 PF30
32 FDO −31 30131 PF31
33 FDO−32 30132 PF32
C0117
® ® selection list 2 Signal configuration DIGOUT
à depending on C0005
See system
manual
(extension)
1 DIGOUT1 30012 pos−ref−ok X5/A1
2 DIGOUT2 30013 POS−IN−TARGET X5/A2
3 DIGOUT3 500 DCTRL−RDY X5/A3
4 DIGOUT4 30101 pos−pfo1 X5/A4
C0118
0
1
HIGH active
LOW active
DIGOUT polarity
Polarity of the terminals X5/Ax
See system
manual
(extension)
1 DIGOUT1 POL 0 X5/A1
2 DIGOUT2 POL 0 X5/A2
3 DIGOUT3 POL 0 X5/A3
4 DIGOUT4 POL 0 X5/A4
Komentarze do niniejszej Instrukcji