EDS94TA10020xxxx EN 1.1 - 10/2008 L 19
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Speed limit value conditioning
Use of further ramp parameter sets
If required, 15 further ramp parameter sets can be parameterised. For the selection of the
ramp parameter sets 1 ...
15, the selection inputs are to be assigned with the corresponding
signals. The selection of the ramp parameter sets is carried out in a binary coded manner.
r Parameter setting: Tab Application parameters dialog level Overview Ramp
generator All ramp parameters
Parameter Lenze setting
Value Unit
C03512/1 Acceleration time 1 0.000 s
C03512/... Acceleration time ... ... ...
C03512/15 Acceleration time 15 0.000 s
C03513/1 Deceleration time 1 0.000 s
C03513/... Deceleration time ... ... ...
C03513/15 Deceleration time 15 0.000 s
C03514/1 S-ramp time 1 0.000 s
C03514/... S-ramp time ... ...
C03514/15 S-ramp time 15 0.000 s
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Activate ramp parameter set 1 a C03009/8
FALSE Activate ramp parameter set 2 C03009/9
FALSE Activate ramp parameter set 4 C03009/10
FALSE Activate ramp parameter set 8 a C03009/11