EDS94TA10020xxxx EN 1.1 - 10/2008 L 29
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Application error messages
4.12 Application error messages
For the output of application-specific error messages an FB instance L_DevApplErr1 of the
function block L_DevApplErr is available.
r Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
r Parameter setting: All parameters tab
Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is
connected to the input DI_bResetError1 of the drive interface.
Error message Error ID Error response
1 Torque follower in limitation 8001 Warning locked
2 - 8000 Error
3 - 8000 Error
4 - 8000 Error
5 - 8000 Error
6 - 8000 Error
7 - 8000 Error
8 - 8000 Error
Parameter Lenze setting
C05900 Module ID 980
C05901/1...8 Error ID 1 ... 8 See table above
C05902/1...8 Error response 1 ... 8 See table above