Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 109
The L_DCO_DriveCommunication library
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.3.5 L_DCO_TransferData
Variables of the L_DCO_TransferData structure
Identifier/data type Information/possible settings
wIndex
WORD
Index number of the parameter to be processed
bySubIndex
BYTE
Subindex of the parameter to be processed
dwData
DWORD
Transmitted/read data
byNrOfByte
BYTE
Number of the transmitted/read bytes
xEnable
BOOL
Activation of the parameter request
FALSE Parameter request is processed
TRUE Parameter request is ignored
xWriteAccess
BOOL
Write/or read access
FALSE Read access
TRUE Write access