The L_DAC_DataConversion library
L_DAC_GetBitOfByte - conversion block
86
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2 L_DAC_GetBitOfByte - conversion block
This function returns the state of an individual bit value as a "BYTE" value.
Inputs
Output signal
L_DAC_GetBitOfByte: New value of the "BYTE" type, which results from the respective input signal.
Function library: L_DAC_DataConversion
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_DAC_GetBitOfByte
BYTE byInput L_DAC_GetBitOfByte BYTE
BYTE byBitNr
Identifier/data type Information/possible settings
byInput
BYTE
Input signal
byBitNr
BYTE
Number (0 ... 7) of the bit of byInput, the status of which is to be determined.