Lenze Drive Server Bus server S7 getting started Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Lenze Drive Server Bus server S7 getting started. Lenze Drive Server Bus server S7 getting started User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Ä!P</ä

Ä!P</äLHandbuch/ManualEDBDRS3!P</Global DriveBusserver S7Ers te S c h ri tte/Getti ng StartedShow/Hide Bookmarks

Strona 2

Busserv er S7L71Busserver S7 DE/EN 1.02.3 Supported PLC hardwareThe following PLC hardware is supported: Siemens S7-300 and S7-400• For S7-400, the co

Strona 3 - Contents

Busserv er S7L72 Busserver S7 DE/EN 1.03 Software installationProceed as follows to install the bus server software on your PC:1. Start Windows.2. Ins

Strona 4

Busserv er S7L73Busserver S7 DE/EN 1.03.1 Component selectionFrom the installation program of the DriveServer with bus server S7 you can select, which

Strona 5 - 1.1 Conventions used

Busserv er S7L74 Busserver S7 DE/EN 1.04 Software configuration4.1 Interface module configurationIf you want to use ”MPI Simatic”, ”PROFIBUS-DP” or ”S

Strona 6

Busserv er S7L75Busserver S7 DE/EN 1.04.2 Bus server configurationThe “S7 c onfiguration tool” program is used for the configuration o f the bus serve

Strona 7 - 2 System requirements

Busserv er S7L76 Busserver S7 DE/EN 1.0Tip!If a plus sign appears in front of the element, this element has sub-elements:A click on the plus sign open

Strona 8

Busserv er S7L77Busserver S7 DE/EN 1.0The PLCs found and the drives c onfigured in the PLC program are listed as configuration e ntries in thetree str

Strona 9 - Show/Hide Bookmarks

Busserv er S7L78 Busserver S7 DE/EN 1.04.2.4 PLC parametersThe below table contains all parameters which are relevant for the PLC configuration. The p

Strona 10 - Busserv er S7

Busserv er S7L79Busserver S7 DE/EN 1.04.2.5 Automatic drive scanningIf the PLC is connected to the PC and the PLC program has already been transmitted

Strona 11 - 3 Software installation

Busserv er S7L80 Busserver S7 DE/EN 1.04.2.6 Manual addition of drivesAs an alternative to using the scan function, you can add the drives manually to

Strona 12 - 3.1 Component selection

Busserv er S7L63Busserver S7 DE/EN 1.0CAUTION:The software is supplied to the user as described in this document. Any risks resulting fromits quality

Strona 13 - WControl panel

Busserv er S7L81Busserver S7 DE/EN 1.04.2.8 Configuration of sub-systemsIf the PLC connected to the PC includes a ”routing function”, it is possible t

Strona 14

Busserv er S7L82 Busserver S7 DE/EN 1.0Tip!Proceed as follows to identify the sub-network ID in the STEP 7 program:1. Start the ”NetPro” service progr

Strona 15

Busserv er S7L83Busserver S7 DE/EN 1.04.2.9 Manual deletion of configuration entriesYou can always delete configuration entries (PLCs, devices, OPC it

Strona 16

Busserv er S7L84 Busserver S7 DE/EN 1.05 Creating a STEP7 project5.1 Overview of the STEP7 blocksThe foll owing figure gives you an o verview of the d

Strona 17

Busserv er S7L85Busserver S7 DE/EN 1.05.2 Typical program flowThe following figure shows the typical sequence of a STEP7 program with OPC access:DBx O

Strona 18

Busserv er S7L86 Busserver S7 DE/EN 1.05.3 Files provided5.3.1 STEP7 libraryThe indivi dual block s are available in form of a library and can be used

Strona 19 - 4.2.7 Drive parameters

Busserv er S7L87Busserver S7 DE/EN 1.05.3.2 STEP7 example programsThe following example programs are part of the bus ser ver S7 delivery package. They

Strona 20

Busserv er S7L88 Busserver S7 DE/EN 1.05.4 Creating new projectsTip!The follo wing description is based on Version 5.0 of STEP7. The dialog boxes used

Strona 21

Busserv er S7L89Busserver S7 DE/EN 1.05.5 Hardware configurationThe Hardware Manager is used to configure the hardware used:• Select the entry CPU 315

Strona 22

Busserv er S7L90 Busserver S7 DE/EN 1.06. Select the corresponding device from the list and use the mouse to drag it onto the graphicallyillustrated P

Strona 23 - 5 Creating a STEP7 project

ContentsL64 Busserver S7 DE/EN 1.01 Pref ace and general information 66...1.1 Conventions used 66...

Strona 24

Busserv er S7L91Busserver S7 DE/EN 1.05.6 Creating a STEP7 programThe Lenze function blocks can be integra ted in different ways. For a simple test, t

Strona 25 - 5.3.1 STEP7 library

Busserv er S7L92 Busserver S7 DE/EN 1.0Example of a transfer parameter list:CALL ”Lenze-DriveServer_FB”, DB100 FB90Tag :=PB_Address :=B#16#9EA_Address

Strona 26

Busserv er S7L93Busserver S7 DE/EN 1.05.6.2 Accessing several drives via OPCThe project is to be expanded to enable communication with several drives.

Strona 27

Busserv er S7L94 Busserver S7 DE/EN 1.0Note!If you want to address drive controllers connected to the PROFIBUS master of the CPU and drivecontrollers

Strona 28

Busserv er S7L95Busserver S7 DE/EN 1.05.7 Testing the STEP7 programWhen the program has been completed, it can be loaded into the PLC and tested. The

Strona 29

Busserv er S7L96 Busserver S7 DE/EN 1.05.8 Optimisation of the cycle timeWhen FB DRIVE is activated, the PLC cycle is always under load, even if no pa

Strona 30

Busserv er S7L97Busserver S7 DE/EN 1.05.9 Accessing PLC dataWith bus server S7, you can access both the parameters of the drive controllers and the PL

Strona 31

Busserv er S7L98 Busserver S7 DE/EN 1.06 Appendix6.1 Time load of the PLC cycleThe function blocks are cyclically called. The PLC cycle is permanently

Strona 32

Busserv er S7L99Busserver S7 DE/EN 1.0Output parameters:• Global Drive Control (GDC) and DriveServer were used to l oad a complete parameter set.• An

Strona 33

Busserv er S7L100 Busserver S7 DE/EN 1.06.3 Communication function parameters6.3.1 FB90 (FB DRIVE)Function block• For every drive one instance is to b

Strona 34

ContentsL65Busserver S7 DE/EN 1.05.7 Testing the STEP7 program 95...5.7.1 Structure of the DriveServer n

Strona 35

Busserv er S7L101Busserver S7 DE/EN 1.06.3.2 FB91 (FB DRIVE CP)Function block• For every drive one instance is to be created.• The function block is b

Strona 36

Busserv er S7L102 Busserver S7 DE/EN 1.06.3.3 FC90 (FC Parameter)Function for parameter data jobs from the PLC.Parameters Data type Possible values/me

Strona 37 - 6 Appendix

Busserv er S7L103Busserver S7 DE/EN 1.0Possible values/meaningData typeParametersR_Value OUT : DINTRead value (FIX32)R_ValueOUT:DINTIf Status= 0x83, a

Strona 38

Busserv er S7L104 Busserver S7 DE/EN 1.06.3.4 FC91 (FC Process Data, 3 words)Function for process data accessConsistent process data transfer is a pre

Strona 39 - 6.3.1 FB90 (FB DRIVE)

Busserv er S7L105Busserver S7 DE/EN 1.06.3.5 FC92 (FC Process Data, 2 words)Function for process data accessThe function FC92 can be used for both con

Strona 40 - 6.3.2 FB91 (FB DRIVE CP)

Busserv er S7L106 Busserver S7 DE/EN 1.06.3.6 FC93 (FC Process Data, 3 words, CP)Function for process data accessConsistent process data transfer is a

Strona 41 - 6.3.3 FC90 (FC Parameter)

Busserv er S7L107Busserver S7 DE/EN 1.06.3.7 FC94 (FC Process Data, 2 words, CP)Function for process data accessThe function FC94 can be used for both

Strona 42

Busserv er S7L108 Busserver S7 DE/EN 1.06.4 Remote maintenance via modemSiemens offers a TS ada pter which can be used for remote maintenance. This ad

Strona 43

Busserv er S7L109Busserver S7 DE/EN 1.06.5 Example project S7-400The example project ”LenzeDriveServer” desc ribed in this chapter can be found in the

Strona 44

Busserv er S7L110 Busserver S7 DE/EN 1.06.5.2 Program blocks usedThe project folder Blocks contains the following program blocks:Block FunctionOB1 Org

Strona 45

Busserv er S7L66 Busserver S7 DE/EN 1.01 Preface and general informationThe DriveServer is a software which provides easy i ntegra tion of drives into

Strona 46

Busserv er S7L111Busserver S7 DE/EN 1.06.5.3 Symbolic variable namesSymbolic variable names are used in the “LenzeDriveServer” example project. These

Strona 47

Busserv er S7L112 Busserver S7 DE/EN 1.06.5.4 OB1/FC4With OB1, only the function FC4 is called, in which all other blocks are called.6.5.5 Process dat

Strona 48

Busserv er S7L113Busserver S7 DE/EN 1.06.5.6 Parameter data accessThe FB90 (FB DRIVE) enables accessing parameter data both via OPC and from the PLC.

Strona 49 - 6.5.2 Program blocks used

Busserv er S7L114 Busserver S7 DE/EN 1.06.5.7 Reading a parameterFC4, network 3UN “TriggerRead”= “TriggerRead”CALL FC 90 //data typesDrivePar_DB :=”S7

Strona 50 - 6.5.3 Symbolic variable names

Busserv er S7L115Busserver S7 DE/EN 1.06.5.8 Writing a parameterFC4, network 4UN “TriggerWrite”= “TriggerWrite”CALL FC 90 //data typesDrivePar_DB :=”S

Strona 51

Busserv er S7L116 Busserver S7 DE/EN 1.06.6 Example project S7-300 with PROFIBUS-CPThe example project ”LenzeDriveServer” desc ribed in this chapter c

Strona 52

Busserv er S7L117Busserver S7 DE/EN 1.06.6.2 Program blocks usedThe project folder Blocks contains the following program blocks:Block FunctionOB1 Orga

Strona 53

Busserv er S7L118 Busserver S7 DE/EN 1.06.6.4 OB1/FC3Call the F3 function in OB1. All other Lenze blocks are called from this function. Then call the

Strona 54

Busserv er S7L119Busserver S7 DE/EN 1.06.6.5 Process data transferFC3, network 1The following call is used to transmit two process data words (2PZD).•

Strona 55

Busserv er S7L120 Busserver S7 DE/EN 1.06.6.6 Parameter data accessThe FB91 (FB DRIVE CP1) enables a ccess parameter data both via OPC and from the PL

Strona 56 - 6.6.3 Symbolic variable names

Busserv er S7L67Busserver S7 DE/EN 1.01.2 Layout of the safety informationAll safety information have a uniform layout:• The icon characterises the ty

Strona 57 - 6.6.4 OB1/FC3

Busserv er S7L121Busserver S7 DE/EN 1.06.6.7 Reading/writing a parameterFor reading a nd writing of parameters it is not important whether the device

Strona 58

Busserv er S7L122 Busserver S7 DE/EN 1.06.7 FAQ - Frequently asked questions and answersQuestion AnswerWhichbaudrateistobesetfortheMPIinterfacemodule

Strona 59

Busserv er S7L123Busserver S7 DE/EN 1.0AnswerQuestionCan you see in the PLC program if the drive controlleris switched on?Yes, you can see this by mea

Strona 60

Busserv er S7L124 Busserver S7 DE/EN 1.0Show/Hide Bookmarks

Strona 61

Busserv er S7L68 Busserver S7 DE/EN 1.02 System requirementsThe following minimum requirements on hardware a nd software must be met in order to use t

Strona 62

Busserv er S7L69Busserver S7 DE/EN 1.02.2 Supported communication channelsThe bus server S7 supports the following communication channels:BusserverS7S

Strona 63

Busserv er S7L70 Busserver S7 DE/EN 1.0CommunicationchannelPC interface PC interfacemoduleTransmissionmediumPLC interface module PLC interface Additio