5.5 Hardware configuration
The Hardware Manager is used to configure the hardware used:
Select the entry CPU 315-2 DP in the STEP7 project structure.
Double-click the symbol Hardware on the right side of the windo w to open the Hardware
Manager.
At this point, the Hardware Manager only lists the CPU-315-2 with integrated DP Master:
5.5.1 Configuring the MPI interface of the CPU
Proceed as follows to configure the MPI interface of the CPU:
1. Right-click the entry CPU315-2 DP(1) to open the context menu.
2. Select the entry Object Properties from the context menu to open the Object Properties dialog
box.
3. Click in the General tab in the Interface group box the Properties button to open the Properties
-MPIinterfacedialog box.
4. Configure the MPI address and the MPI sub-network in the Parameters tab and confirm the
settings with OK.
5.5.2 Configuring the PROFIBUS interface of the CPU
Proceed as follows to configure the PROFIBUS interface of the CPU:
1. Select the DP Master line in the slot table.
2. Select Insert
WDP Master System unless a DP master system has already been automatically
created.
Tip!
If a DP master system has alread y been automatically created:
Right-click the entry DP Master System to open the c ontext menu.
Select the entry Object Properties from the context menu to open the DP Master System
dialog box.
3. Enter the DP device address of the DP master in the DP Master System dialog box.
4. Create a new PROFIBUS sub-network with the profile DP andthedesiredbaudrate.
5. Select View
WCatalog to open the hardware catalog to add PROFIBUS devices.