6.3.5 FC92 (FC Process Data, 2 words)
Function for process data access
The function FC92 can be used for both consistent and i nconsistent process da ta transfer.
Parameters Data type Possible values/meaning
EA_Address IN: INT I/O address of the process data channel
e. g. 1008
Enable IN: BOOL
TRUE Drive enabled
E
n
a
b
l
e
I
N
:
B
O
O
L
FALSE Drive inhibited
QSP IN: BOOL
TRUE Quick stop (QSP) active
Q
S
P
I
N
:
B
O
O
L
FALSE Quick stop (QSP) not active
Reset IN: BOOL FALSE äTRUE TRIP reset executed
Setpoint1 IN: INT Setpoint process value (AIF-IN:W1)
ControlWord IN: WORD Control word according to DRIVECOM specification
Bit0 ... Bit4 are hidden and cannot be written.
RDY OUT: BOOL
TRUE Drive is ready for operation
O
U
O
O
FALSE Drive is not ready for opera tion
TRIP OUT: BOOL
TRUE Drive signals TRIP
O
U
O
O
FALSE Drive does not signal TRIP
ActualValue1 OUT: INT Actual process value (AIF-OUT:W1)
StatusWord OUT: WORD Status word according to DRIVECOM specification