Lenze Drive Server Bus server S7 getting started Instrukcja Użytkownika Strona 43

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 63
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 42
Busserv er S7
L
104 Busserver S7 DE/EN 1.0
6.3.4 FC91 (FC Process Data, 3 words)
Function for process data access
Consistent process data transfer is a prerequisite for using this function!
Parameters Data type Possible values/meaning
EA_Address IN: INT I/O address of the process data channel
e. g. 1008
Enable IN: BOOL
TRUE Drive enabled
E
n
a
b
l
e
I
N
:
B
O
O
L
FALSE Drive inhibited
QSP IN: BOOL
TRUE Quick stop (QSP) active
Q
S
P
I
N
:
B
O
O
L
FALSE Quick stop (QSP) not active
Reset IN: BOOL FALSE äTRUE TRIP reset executed
Setpoint1 IN: INT Setpoint process value (AIF-IN:W1)
Setpoint2 IN: INT Setpoint process value (AIF-IN:W2)
ControlWord IN: WORD Control word according to DRIVECOM specification
Bit0 ... Bit4 are hidden and cannot be written.
RDY OUT: BOOL
TRUE Drive is ready for operation
O
U
O
O
FALSE Drive is not ready for opera tion
TRIP OUT: BOOL
TRUE Drive signals TRIP
O
U
O
O
FALSE Drive does not signal TRIP
ActualValue1 OUT: INT Actual process value (AIF-OUT:W1)
ActualValue2 OUT: INT Actual process value (AIF-OUT:W2)
StatusWord OUT: WORD Status word according to DRIVECOM specification
Show/Hide Bookmarks
Przeglądanie stron 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 62 63

Komentarze do niniejszej Instrukcji

Brak uwag