8.6 Code table
Drive PLC
Appendix
8−16
L
DrivePLC DE 6.0
8.6 Code table
How to read the code table:
Column Abbreviation Meaning
Code C0168
1
2
…
8
Code C0168
Subcode 1 of code C0168
Subcode 2 of code C0168
…
Subcode 8 of code C0168
[C0156] Parameter value of code can only be changed when controller is inhibited.
LCD Keypad LCD
Lenze
Lenze setting of the code
g Display code (can only be displayed)
* The "Info" column contains more information.
Selection 1 {1 %} 99 Minimum value {smallest step/unit} maximum value
Info Additional information on code
Code LCD
Possible settings
Info
Lenze Selection
[C0002] Par load 0 Load parameter set
Only possible when PLC has been stopped.
Parameter set 1 is automatically loaded after
power−on.
0 Load Lenze setting into RAM
1 Load parameter set 1 into RAM
C0003 Par save 0 Save parameter set
Also possible when PLC is in operation.
0 Saving completed
1 Non−volatile saving of parameter set 1
C0004 Op display 372 Keypad operating display
Keypad will indicate selected code in the operating
level if no other status indications of C0183 are active.
All available codes
C0009 LECOM address 1 LECOM controller address
(bus device number for operation via interface)
10, 20, ..., 90 reserved for broadcast to device groups
for RS232, RS485, fibre optics.
1 {1} 99
C0011 Nmax 3000 Reference code for speed scaling
500 {1 rpm} 16000
C0043 Trip reset Current TRIP reset
0 Trip reset
1 Trip active
C0067 Act trip
g
Current TRIP
("0" is displayed for FAIL−QSP, warning and message.)
C0093 PLC ident
g
Controller identification
C0094 Password 0 Keypad password protection
Parameter password protection for the keypad.
When the password is activated, only user−menu codes
can be accessed.
For extended password protection, please see C0096.
0 {1} 9999
0 = No password protection
Komentarze do niniejszej Instrukcji