9300 Servo PLC
Appendix
3.6 Code table
3−131
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0157 Stat. FreeBit
g
Status word DCTRL: Status of freely definable bits
01
1 DCTRL_bStateB0_b
2 DCTRL_bStateB2_b
3 DCTRL_bStateB3_b
4 DCTRL_bStateB4_b
5 DCTRL_bStateB5_b
6 DCTRL_bStateB14_b
7 DCTRL_bStateB15_b
C0161 Act trip
g
Current TRIP
See C0168/1
"0" is displayed for FAIL−QSP, warning and message.
C0167 Reset failmem 0 History buffer reset
0 No function
1 Delete all entries in history buffer
C0168 Fail number
g
History buffer: Error messages
List with error messages in order of occurrence.
All error messages
1 Current error message
2 Last error message
3 Last but one error message
4 Last but two error message
5 Last but three error message
6 Last but four error message
7 Last but five error message
8 Last but six error message
C0169 Failtime
g
History buffer: Power−up time
List with the power−up times until an error message
occurs in C0168/x.
Refers to the elapsed time meter (C0179)
0 {1 s} 65535
1 Current error message
2 Last error message
3 Last but one error message
4 Last but two error message
5 Last but three error message
6 Last but four error message
7 Last but five error message
8 Last but six error message
C0170 Counter
g
History buffer: Frequency of error messages
List which indicates how many times an error occurred
in C0168/x.
0 {1} 65535
1 Current error message
2 Last error message
3 Last but one error message
4 Last but two error message
5 Last but three error message
6 Last but four error message
7 Last but five error message
8 Last but six error message
[C0172] 0V reduce 10 Threshold for activating the braking torque derating before