3.6 Code table
9300 Servo PLC
Appendix
3−138
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0471 FCODE 32bit 0 Freely configurable code (digital signals)
Variables assigned via FCODE_FreeCodes:
FCODE_bC471Bit0_b ... FCODE_bC471Bit31_b
C0471 has the same memory address as code C0470.
0 {1} 4294967296
C0472 FCODE analog Freely configurable code (relative analog signals)
−199.99 {0.01 %} 199.99
1 0 FCODE_bC472_1_a
2 0 FCODE_bC472_2_a
3 100 FCODE_bC472_3_a
4 0 FCODE_bC472_4_a
... ... ...
20 0 FCODE_bC472_20_a
C0473 FCODE abs Freely configurable code (absolute analog signals)
−32767 {1} 32767
1 1 FCODE_bC473_1_a
2 1 FCODE_bC473_2_a
3 0 FCODE_bC473_3_a
... ... ...
10 0 FCODE_bC473_10_a
C0474 FCODE PH Freely configurable code (phase signals)
−2147483648 {1} 2147483647
1 0 FCODE_dnC474_1_p
... ... ...
5 0 FCODE_dnC474_5_p
C0475 FCODE DF Freely configurable code (phase difference signals)
−16000 {1 rpm} 16000
1 0 FCODE_nC475_1_v
2 0 FCODE_nC475_2_v
[C0490] Feedback pos 0 Feedback system for the position controller
C0490 = 0, 1, 2 can be mixed with
C0495 = 0, 1, 2.
C0490 = 3, 4 also sets C0495 to the same value.
0 Resolver at X7
1 Encoder TTL at X8
2 Sin/cos encoder at X8
3 Absolute value encoder ST at X8
4 Absolute value encoder MT at X8
[C0495] Feedback n Feedback system for the speed controller
C0495 = 0, 1, 2 can be mixed with
C0490 = 0, 1, 2.
C0495 = 3, 4 also sets C0490 to the same value.
0 Resolver at X7
1 Encoder TTL at X8
2 Sin/cos encoder at X8
3 Absolute value encoder ST (single turn) at X8
4 Absolute value encoder MT (multi turn) at X8
C0496 NactFilter on 0 Activation: Actual speed value filter time constant PT1
(C0497)
0 Not active
1 Active
C0497 Nact filter 2.0 Actual speed value filter time constant PT1. Has both an
effect on the system variable MCTRL_nNAct_a and on the
following speed control.
0.0 {0.1 ms} 50.0
0 ms = switched off
Komentarze do niniejszej Instrukcji